TMCF Protocols: Southern Blotting
互联网
BUFFERS:
1) Prehybridization/hybridization buffer
1% SDS
6X SSC
10 % dextran sulfate
100mg salmon sperm DNA/ml (added with the radioactive probe)
Note: Store hybridization buffer at 4 degrees and warm to 65 degrees prior to use since the dextran sulfate tends to precipitate during storage.
2) 20X SSC Stock Solution
Add 175.3g NaCl and 88.2g Sodium Citrate to 800 ml distilled water and pH to 7.0.
Add water to 1000ml and autoclave to sterilize.
PROTOCOL:
Digest 10ml (10mg) of the sample DNA with the appropriate restriction enzyme.
Mix well and digest overnight at the appropriate temperature for the enzyme of your choice.This is necessary to ensure proper digestion of the genomic DNA.
Spin down the digested samples and run on a 0.8% TAE (or TBE) agarose gel. Be sure to include both a negative and a positive control and a size marker. Run the gel at no greater than 60V until proper separation of the desired bands is achieved. This generally takes from 6-18 hours depending on the size differential between the expected bands.
Take a picture of the stained gel. Be sure to use a UV ruler so that the size of the bands can be estimated. If desired, you can trim the gel to remove areas which will not contain the bands of interest.
Optional: Shake the gel in 0.2M HCl for 10 minutes. This step hydrolyzes the DNA breaking it into smaller fragments which are transferred more quickly to the nitrocellulose membrane.However, too long an incubation will destroy the DNA completely, therefore it is not advised to perform this step unless the bands of interest are expected to be greater than 12-15 kb in size.
Shake the gel in 0.5M NaOH/1.5M NaCl for 30minutes. Prewet the nylon filter according to the manufacturers instructions and set up the blot as per the diagram below. Transfer overnight.
Rinse the filter in 2X SSC buffer. Place between two sheets of Whatman paper and bake at 80 degrees under a vacuum for 1 hour, or crosslink with U.V. light.
Prehybridize your blot for at least 2 hours at 65 degrees, add radioactive probe and hybridize overnight. The amount of buffer that you add to your blot depends upon your hybridization setup but should be enough to fully cover the blot.
Wash the filter: 1x 15minutes in 2X SSC 1% SDS, room temperature
2x 30minutes in 0.1X SSC 0.1% SDS, 65 degrees
Dry the blot briefly between two sheets of Whatman paper, wrap the blot in saran wrap and expose to film overnight.