DNA Sequencing by Chemiluminescent Detection
互联网
497
The development of fluorescent, calorimetric, and more recently chemiluminescent detection systems have opened the way to replace radioactive detection for DNA sequencing (1–3). Although the bulk of DNA sequencing is still carried out using radioactive detection, the availability of better chemistries, equipment, and protocols make nonradioactive detected DNA sequencing increasingly popular. This chapter describes a protocol for standard Sanger M 13 DNA sequencing (4 ,5 ) using enzymatically triggered 1,2-dioxetane chemiluminescence (6 ,7 ) for the detection, The principle of this method is illustrated in Fig. 1 . The target DNA is immobilized onto a membrane and labeled with the enzyme alkaline phosphatase via an affinity system, such as the biotin/(strept)avidin or the digoxigenin system. Upon adding the dioxetane substrate to the membrane, the phosphatase will deprotect 1,2-dioxetane molecules by cleaving off the phosphate group, thereby initiating the chemiluminescent reaction that can then be detected as visible light. The main features of this detection system are speed, with detection times between l–30 min, sensitivity, between lo–100 attomoles of target DNA, and compatibility, since the method requires only equipment available in any molecular biology laboratory and allows the generation of the same data format (e.g., X-ray film hardcopy) as with radioactive detection. Since its first description in 1989 (3 ) several modifications and improvements have been reported for chemiluminescent detected DNA sequencing (7–11).
Fig. 1. Schematic representation of chemiluminescent detection of membrane immobilized DNA.