Characterization of dna
LEVEL I
Materials
-
DNA sample
-
SSC buffer
- UV spectrophotometer 3 and quartz cuvettes
Procedure
-
Dissolve a small quantity of your extracted DNA in 3.0 ml of 0.1X SSC.
-
Turn on and blank a UV spectrophotometer at 220 nm (use 0.1X SSC as the blank). Determine the absorbance of your sample DNA at 230 nm.
-
Change the wavelength to 230 nm, reblank the spectrophotometer and measure the absorbance of the sample at 230 nm.
-
Increment the wavelength by 10 nm and repeat blanking and measuring the absorbance until readings are taken through 300 nm.
-
Compute the absorbance ratio 260 nm to 280 nm. Pure DNA (without protein or RNA) will have a 260:280 absorbance ratio of 1.85. RNA will have a 260:280 ratio of 2.0.
-
Plot the absorbance spectrum of your sample and indicate the 260:280 ratio, as well as the amount of protein contamination on the graph.