丁香实验_LOGO
登录
提问
我要登录
|免费注册
点赞
收藏
wx-share
分享

The Lymphocyte Crossmatch by Flow Cytometry for Kidney Transplantation

互联网

423
The flow cytometric lymphocyte crossmatch is a standard technique for evaluating the compatibility of potential kidney transplant recipients and donors. Recipient serum is incubated with donor lymphocytes and the latter are analysed in a flow cytometer for the presence of bound IgG antibodies. An increase in the level of IgG binding compared to a negative control indicates the presence of donor-specific antibodies which may lead to deleterious graft function. Described here is a method to perform T and B lymphocyte crossmatching in the same tube to detect IgG donor-reactive antibodies.
提问
扫一扫
丁香实验小程序二维码
实验小助手
丁香实验公众号二维码
扫码领资料
反馈
TOP
打开小程序